Quantum SS9000 3000 Cubic Feet

Quantum SS9000 3000 Cubic Feet

220V
Model Quantum SS9000 
Cellar Size 
3,000 cu. ft.* 
BTU/h
 (85°F condenser air intake temperature) 9572 
CFM 
810
Dimensions 
Evaporator: 29.5”L x 30.9”W x 19.8”H • Condenser: 24”L x 18.98”W x 16.16”H
Refrigerant 
R-134a
HP
 3.76
Voltage Rating
 Evaporator: 115V (15 amp dedicated circuit required) Condenser: 230V (15 amp dedicated circuit required)
Weight 
(lbs) Evaporator: 96 • Condenser: 75
Amps 
Evaporator: 3.2 (running amps) Condenser: LRA 35/RLA 6.5
Line Set
 Liquid Line 3/8” • Suction Line (Less than 50ft. 3/4”) (Greater than 50ft. 7/8”)
Drain Line
 ¾” ID CPVC
Installation 
Evaporator can be installed up to 25 duct feet away from the cellar. Condensing unit can be installed for up to 100 line feet from the evaporator unit.
Thermostat 
Advanced digital display (50ft. cable), liquid-temperature-measuring bottle probe (50ft. cable)
Temp. Delta 
Can maintain a 55°F cellar temperature with up to 110°F condenser air intake temperature
Warranty 
Two-year limited warranty (parts and labor)

Condensing Unit HP 1.0 HP
Voltage Rating 220V (15-amp dedicated circuit required)
Weight (lbs) 64
Amps LRA 20, RLA 4.25, FLA 4389
Line Set Liquid Line 3/8” OD • Suction Line (Less than 50ft. 5/8” OD) (Greater than 50ft. 3/4” OD)
Installation Condensing Unit can be installed up to 100 line feet from evaporator unit
Temp. Delta Can maintain a 55°F cellar temperature with up to 120°F condenser air intake temperature
Warranty Two-year limited warranty (parts and labor)

220V HE
Model
 9000
Cellar Size 
3000 cu. ft.*
Fan Speed
 High
BTU/h
 (60°F condenser air intake temperature) Sensible / Total 10985 / 11316
BTU/h
 (75°F condenser air intake temperature) Sensible / Total 10711 / 11019 
BTU/h
 (85°F condenser air intake temperature) Sensible / Total 10145 / 10786 
dBA 
52 
Dimensions 
29.5”L x 30.9”W x 19.8”H
Refrigerant
 R-134a
Voltage Rating  
120V (15-amp dedicated circuit required)
Weight (lbs) 
96
Amps
 9.2 (Running Amps)
Drain Line 
3/4” ID CPVC
Installation 
Evaporator unit can be installed up to 25 duct feet away from the cellar.
Thermostat
 Advanced digital display (50-ft. cable), liquid-temperature-measuring bottle probe (50-ft. cable), 24V – customer supplied
Temp. Delta 
Can maintain a 55°F cellar temperature with up to 120°F condenser air intake temperature
Warranty 
Two-year limited warranty (parts and labor)

Condenser
dBA 48
Dimensions 31.18″L x 10.75″W x 21.8″H
Condensing Unit HP 1.0 HP
Voltage Rating 220V (15-amp dedicated circuit required)
Weight (lbs) 64
Amps LRA 20, RLA 4.25, FLA 4389
Line Set Liquid Line 3/8” OD • Suction Line (Less than 50ft. 5/8” OD) (Greater than 50ft. 3/4” OD)
Installation Condensing Unit can be installed up to 100 line feet from evaporator unit
Temp. Delta Can maintain a 55°F cellar temperature with up to 120°F condenser air intake temperature
Warranty Two-year limited warranty (parts and labor)