Skip to product information
1 of 9

Root Stock Wine Design

Platinum Split 4000 Ducted 1000 Cubic Feet

Platinum Split 4000 Ducted 1000 Cubic Feet

110V
Model
 4000
Cellar Size 1000 cu. ft.*
BTU/h (85°F condenser air intake temperature) Medium: 3120 • High: 3195
CFM 200
Dimensions Evaporator: 16.1”L x 20.5”W x 15.5”H • Condenser: 16.08”L x 16.23”W x 12.61”H
Refrigerant R-134a
Voltage Rating Evaporator: 115V (15 amp dedicated circuit required) Condenser: 115V (15 amp dedicated circuit required)
Weight (lbs) Evaporator: 57 • Condenser: 56
Amps Evaporator: 1 (running amps) • Condenser: LRA 43/RLA 8 Evaporator: 1 (running amps)
Line Set Liquid Line 1/4” • Suction Line (Less than 50ft. 1/2”) (Greater than 50ft. 5/8”)
Duct Size 8” Supply • 10” Return
Drain Line ½” ID clear plastic tubing (not provided)
Installation Evaporator can be installed up to 25 duct feet away from the cellar. Condensing unit can be installed up to 100 line feet from the evaporator unit.
Thermostat Advanced digital display (50ft. cable), liquid-temperature-measuring bottle probe (50ft. cable)
Temp. Delta Can maintain a 55°F cellar temperature with up to 110°F condenser air intake temperature
Warranty Two-year limited warranty (parts and labor)
Options: Exterior condenser housing, 24V thermostat conversion kit, condenser coil coating

220V
EVAPORATOR

Model 4000
Cellar Size 1000 cu. ft *
Fan Speed Medium | High
BTU/h (60°F condenser air intake temperature)  4565 / 5273 | 4786 / 5488  Sensible / Total
BTU/h (75°F condenser air intake temperature)  4177 / 4561 | 4601 / 4669  Sensible / Total
BTU/h (85°F condenser air intake temperature)  3957 / 4315 | 4244 / 4453  Sensible / Total
dBA 56 | 62
Dimensions 16.1”L x 20.5”W x 15.5”H
Refrigerant R-134a
Voltage Rating 120V (15-amp dedicated circuit required)
Weight (lbs) 54
Amps 2.2 (Running Amps)
Drain Line 1/2″ ID clear plastic tubing (not provided)
Installation Evaporator unit is installed in the cellar.
Thermostat Advanced digital display (50-ft. cable), liquid-temperature-measuring bottle probe (retractable cable), 24V – customer supplied
Temp. Delta Can maintain a 55°F cellar temperature with up to 120°F condenser air intake temperature
Warranty Two-year limited warranty (parts and labor)

Condenser
Fan Speed Medium | High
dBA 45
Dimensions 31.18″L x 10.75″W x 21.8″H
Condensing Unit HP 0.6 HP
Voltage Rating 220V (15-amp dedicated circuit required)
Weight (lbs) 55
Amps LRA 13.2, RLA 3.19, FLA 3.66
Line Set Liquid Line 1/4” OD • Suction Line (Less than 50ft. 1/2” OD) (Greater than 50ft. 5/8” OD)
Installation Condensing Unit can be installed up to 100 line feet from evaporator unit
Temp. Delta Can maintain a 55°F cellar temperature with up to 120°F condenser air intake temperature
Warranty Two-year limited warranty (parts and labor)

View full details