Skip to product information
1 of 8

Root Stock Wine Design

Mini Ceiling Mount 500 Cubic Feet

Mini Ceiling Mount 500 Cubic Feet

110V
Cellar Size
 500 cu. ft.*
BTU/h (85°F condenser air intaketemperature)
Low: 1950 • Med: 2167
CFM 107
Dimensions Evaporator: 25.05” L x 11.34” W x 11.17” H • Condenser: 13.97”L x 15.85”W x 9.86”H
Refrigerant R-134a
HP 0.7
Voltage Rating Evaporator: 115V (15 amp dedicated circuit required) • Condenser: 115V (15 amp dedicated circuit required)
Weight (lbs) Evaporator: 40 • Condenser: 38.8
Amps Evaporator: 1 (running amps) • Condenser: LRA 26/RLA 4.4
Line Set Liquid Line 1/4” • Suction Line (Less than 50ft. 3/8”) (Greater than 50ft. 1/2”)
Drain Line ¼” ID clear plastic tubing (not provided)
Installation Evaporator is installed in the cellar. Condensing unit can be installed up to 100 line feet from the evaporator unit.
Thermostat Advanced digital display (50ft. cable), liquid-temperature-measuring bottle probe (50ft. cable )
Temp. Delta Can maintain a 55°F cellar temperature with up to 110°F condenser air intake temperature
Warranty Two-year limited warranty (parts and labor)

220V
EVAPORATOR
Cellar Size
 500 cu. ft *
Fan Speed 
Low Medium
BTU/h 
(60°F condenser air intake temperature) Sensible / Total – 2442 / 3131
BTU/h 
(75°F condenser airintake temperature) Sensible / Total – 2132 / 2592 
BTU/h
 (85°F condenser air intake temperature) Sensible / Total – 2084 / 2514
Dimensions
 22.05”L x 11.08”W x 11.34”H
Refrigerant
 R-134a
Voltage Rating
 120V (15-amp dedicated circuit required)
Weight (lbs) 
35
Amps
 0.64 (Running Amps)
Drain Line 
1/4″ ID clear plastic tubing (not provided) – Rigid tube recommended
Installation 
Evaporator unit is installed in the cellar. Condensing unit can be installed up to 100 line feet from the evaporator unit.
Thermostat 
Advanced digital display (50-ft. cable), liquid-temperature-measuring bottle probe (50-ft. cable), 24V – customer supplied
Temp. Delta 
Can maintain a 55°F cellar temperature with up to 120°F condenser air intake temperature
Warranty 
Two-year limited warranty (parts and labor)

CONDENSER
dBA 48
Dimensions 
31.18″L x 10.75″W x 21.18″H
Condensing Unit HP
 0.35HP
Voltage Rating 
220V (15-amp dedicated circuit required)
Weight (lbs)
 51
Amps 
LRA 5.3A, RLA 1.55A, FLA 1.7A
Line Set 
Liquid line 1/4” OD; Suction line 3/8” OD (less than 50 ft.), 1/2” (greater than 50 ft.)
Installation
 Evaporator unit is installed in the cellar. The condensing unit is installed up to 100 line feet from the evaporator unit.
Temp. Delta
 Can maintain a 55°F cellar temperature with up to 120°F condenser air intake temperature.
Warranty 
Two-year limited warranty (parts and labor)

View full details